Welcome to Indotrade.co
Sign In | Sign Up
Priority Member Indotrade Priority14th Year
OPRIMA LABORATORY / PT OCTA PRIMA LESTARI
http://indotrade.co/oprima/
PT OCTA PRIMA LESTARI , Rukan Mitra Matraman Blok B-12 Jl Matraman Raya 148 Jakarta 13150 TLP : 087781122777 - 081398855242 - 85902391 - 85918154 - 85918155 - 8512595 - 081510069705
Contact Information
Name:

Mrs. HELEN [Sales]

E-mail:
Send Message
Homepage:

Phone Number:

Phone number of Mrs. HELEN at JAKARTA

Fax Number:

Fax number of Mrs. HELEN at JAKARTA

Address:

JL. MATRAMAN RAYA NO 148 , BLOK B-12
JAKARTA 13150, Jakarta
Indonesia

Average User Review

There is no review for this company

Write a review
Language :

Sell

PORTABLE SPECTROPHOTOMETER DR 2800[Feb. 12, 2012 20:48:52]
Quantity Order:
Payment MethodCashier Order
Quantitywww.octaprimalestari.com
Pack. & Delivery1 UNIT
OriginUnited States
PORTABLE SPECTROPHOTOMETER DR 2800
Made in HACH - USA.

With Lithium Battery

DR 2800 Portable spectrophotometer adds new power to your work, in the lab or in the field.

* Touch screen display with intuitive user interface
* USB ports for easy program updates and printer/ accessory connections
* Over 240 pre-installed analytical methods.
* Automatic test recognition when used with TNTplus barcoded vial tests

* Small footprint
* Open measurement
* Runs on either line power or included lithium-ion battery
* Optional Pour-Thru Cell accessory for high volume analysis and trace level measurement

DR 2800 Portable Spectrophotometer with Lithium-Ion Battery.

Specifications :

Operating Mode: Transmittance ( % ) , Absorbance and Concentration
Source Lamp: Tungsten
Wavelength Range: 340 to 900nm
Wavelength Accuracy: ï ¿ ½ 1.5 nm
Wavelength Resolution: 1 nm
Wavelength Calibration: Automatic
Wavelength Selection: Automatic, based on method selection
Spectral Bandwidth: 5 nm
User-entered Calibrations up to 50
Data Logging 500 points
Automatic Method Recognition With TNTplus vial tests
10-fold measurement and averaging With TNTplus vial tests
Display Backlit, greyscale LCD touch screen
External Outputs USB ( 1 master, 1 slave)
Cell Compatibility 1" square, 1" round, 1-cm square, 1-cm x 5-cm, Multipath 1" / 1-cm, 16-mm round, 13-mm round
Export Capability .csv ( comma-separated values) file
Languages English, French, German, Italian, and Spanish ( Please ask Hach Customer Service about availability of Chinese, Czech, Dutch, Hungarian, Japanese, Korean, Portuguese, and Russian.)

Physical and Environmental
Width: 216 mm ( 8.5 in.)
Height: 132 mm ( 5.2 in.)
Depth: 330 mm ( 13 in.)
Weight: Without battery: 8.95 lbs. ( 4.06 kg)
With battery: 9.65 lbs. ( 4.38kg)
Operating Requirements: 10 - 40 ï ¿ ½ C ( 50 - 104 ï ¿ ½ F) , max. 90% relative humidity ( non-condensing)
Storage Requirements: -25 - 60 ï ¿ ½ C ( -13 - 140 ï ¿ ½ F) max. 80% relative humidity ( non-condensing)

Power Specifications:
Mains connection: Universal power supply 100-240V, 47-63Hz, with exchangeable plug adapters for EU, GB, US, China; Battery ( Optional)
Interfaces: USB 1.1
Enclosure rating IP 41

* Home
* Info Central
* Support
* Tools
* What' s New
* Corporate
* Contact Us

Parameter/ Range/ Reagent Information

Chemical Oxygen Demand ( COD)

Method Range EDL Proc. Approved Reagent Ordering
Reactor Digestion, Method 8000 3-150 mg/ L COD USEPA , USEPA TNTplus Chemical Oxygen Demand ( COD) Reagent, Low Range ( 3-150 mg/ L) , 150 tests ,
TNTplus Chemical Oxygen Demand ( COD) Reagent, Low Range ( 3-150 mg/ L) , 25 tests ,
COD Digestion Vials, Low Range, 3 to 150 mg/ L COD, pk/ 25 ,
COD Digestion Vials, Low Range, 3 to 150 mg/ L COD, pk/ 150
Reactor Digestion, Method 8000 20-1500 mg/ L COD USEPA , USEPA TNTplus Chemical Oxygen Demand ( COD) Reagent, High Range ( 20-1500 mg/ L) , 150 tests ,
TNTplus Chemical Oxygen Demand ( COD) Reagent, High Range ( 20-1500 mg/ L) , 25 tests ,
COD Digestion Vials, High Range, 20 to 1, 500 mg/ L COD, pk/ 150 ,
COD Digestion Vials, High Range, 20 to 1, 500 mg/ L COD, pk/ 25
Reactor Digestion, Method 8000 200 - 15, 000 mg/ L COD COD Digestion Vials, High Range Plus, 200 to 15, 000 mg/ L COD, pk/ 150 ,
COD Digestion Vials, High Range Plus, 200 to 15, 000 mg/ L COD, pk/ 25
Reactor Digestion, Method 8000 3 - 150 mg/ L COD COD Digestion Vials, Ultra Low Range, 1 to 40 mg/ L COD, pk/ 150 ,
COD Digestion Vials, Ultra Low Range, 1 to 40 mg/ L COD, pk/ 25

Copper

Method Range EDL Proc. Approved Reagent Ordering
Bicinchoninate, Method 8026 0.04 to 5.00 mg/ L 0.04 mg/ L Copper Reagent, CuVerï ¿ ½ 2, 25/ AccuVacï ¿ ½ Ampules
You have [3] new inquiries. Go to Member Menu
Home - Trade List - Product List - Inquiry List - Cooperation List - Company List
Copyright © 2024 Indotrade.co. All Rights Reserved.